Skip to content
GEVSELEVATING TRUST. EVERY FLOOR.

MRL · Traction · Hydraulic

Passenger Elevators in Pune

Lifts that carry people in apartment towers, housing societies, offices and institutions, sized to the building's height and traffic.

Compare elevator drive systems and project requirements

Elevator technology in a modern building

Illustrative photography

Elevator cabin and landing detail
Elevator control panel detail

Technology overview

MRL · Traction · Hydraulic

Elevator technology overview
Elevator drive system detail
Elevator installation detail

Quick answer

What is elevator technology?

A passenger elevator carries people between the floors of residential and commercial buildings. Choosing one means matching capacity and speed to how many people use the building at peak times, fitting the shaft, pit and overhead space, and planning maintenance for its working life. GEVS supplies and maintains passenger lifts for buildings across Pune.

  • Elevator capacity and speed

    Capacity & speed

  • Elevator shaft, pit and overhead

    Shaft, pit, overhead

  • Elevator maintenance

    Maintenance

Technology selection

How should elevator technology be evaluated?

  • Elevator planning for residential buildings01

    Housing societies and apartment towers

    The everyday way residents and visitors move

  • Elevator planning for commercial buildings02

    Office and mixed-use buildings

    Handles peak arrival and departure traffic

  • Elevator planning for new construction03

    Hotels, schools and institutions

    Step-free access for guests, staff and students

  • Elevator planning for an existing building04

    Buildings replacing an old lift

    A new lift can often reuse the existing shaft

Evaluating elevator technology options

Choose it when…

  • People, rather than goods or stretchers, are the main load
  • The building has three or more floors used daily by many people
  • You can plan the shaft now, or an existing shaft can be reused

Consider an alternative when

Selection

Compare systems against the building requirements.

System selection depends on the building, intended use, travel requirements, available space, power and verified technical specifications. These factors should be reviewed before choosing a configuration.

  1. Building height and elevator travel01

    Building and travel

    Floors, travel height and stops help define system requirements.

  2. Elevator capacity and passenger traffic02

    Capacity and traffic

    Expected users and usage patterns inform capacity requirements.

  3. Elevator drive and power equipment03

    Power and drive

    Drive arrangement and electrical provision must be checked.

  4. Elevator shaft and available space04

    Shaft and space

    Shaft dimensions, pit and overhead constrain feasible options.

How it works

How elevator drive systems are evaluated

Most passenger lifts are traction lifts. Steel ropes or belts connect the car to a counterweight over a grooved wheel (the sheave) turned by the machine. Because the counterweight balances most of the car's weight, the motor only has to move the difference.

The controller registers calls from the landing and car panels, decides the direction of travel and slows the car to stop level with each floor. Safety circuits, door interlocks and brakes stop the lift if anything is out of place.

Elevator traction drive and guide rails
Elevator controls and operating equipment
Review shaft, pit and overhead requirements →
Traction lift with machine room, in sectionMACHINE ROOM01020304Machine & sheaveControllerGuide railsCarPitCounterweightOVERHEAD
Traction layout: ropes run over a motor-driven sheave, lifting the car on one side while a counterweight descends on the other. The machine can sit in a room above the shaft or inside it (MRL).

Features

Technology considerations

  • 01

    Automatic Rescue Device (ARD)

    What it does
    On power failure, battery power moves the car to a floor and opens the doors
    Why it matters
    Nobody stays trapped between floors during a power cut
  • 02

    Car and landing operating panels (COP / LOP)

    What it does
    Call buttons, floor position, direction and status messages
    Why it matters
    Clear, simple operation for every user, including elderly passengers
  • 03

    Door interlocking

    What it does
    The lift cannot run unless car and landing doors are safely closed
    Why it matters
    Prevents the most common lift accident — falling into an open shaft
  • 04

    Documented cabin designs

    What it does
    Wall, floor, panel, handrail, lighting and ventilation from a published catalogue
    Why it matters
    You see exactly what you are choosing before you order

Specification

Technology specifications

Configured per building, then written into the quotation.

Passenger Elevators specifications
ParameterValue
Elevator typePassenger / Home / Hospital / Goods
Drive technologyMRL traction / Machine-room traction / Hydraulic
Rated loadkg and persons, where applicable
Rated speedm/s
Number of stopsAs per building design
Travel heightmm or m
Cabin dimensionsWidth × depth × height (mm)
Shaft dimensionsWidth × depth (mm)
Pit depthmm
Overhead clearancemm
Door configurationCentre-opening / Telescopic / Manual swing, as applicable
Clear door openingWidth × height (mm)
Electrical supplyVoltage, phase, frequency
Motor and driveMotor type, rated power, VVVF drive where applicable
ControllerManufacturer, model and control features
Emergency rescueARD configuration and operating method
Safety systemsDoor interlocks, overload protection, brakes and other applicable devices
Cabin finishStainless steel, glass, powder-coated finish and flooring options
Applicable standardsRelevant Indian standards and local statutory requirements
Installation conditionsStructural loads, fixing requirements and site readiness

Civil & electrical

Space and power requirements

Elevator shaft, pit and overhead requirements

Shaft, pit and overhead

The shaft width and depth, pit depth and overhead height are set by the car size, door type and drive. In a new building these are designed in; in an existing building we check whether the current shaft fits the lift you need.

Read: shaft, pit and overhead requirements
Electrical supply for an elevator system

Single-phase or three-phase power?

Passenger lifts in multi-storey buildings usually run on a three-phase supply with a dedicated feeder and earthing. We confirm the electrical requirements with your consultant or electrician during the survey.

Read: single-phase vs three-phase power

Comparing elevator systems for a new project? Start with a technical review.

Request Technical Consultation

Honest trade-offs

Trade-offs and limitations

Advantages

  • Configurable for low-rise and mid-rise buildings
  • Machine room-less or machine-room layouts
  • Wide range of documented cabin interiors
  • Battery-backed rescue (ARD) during power failure

Limitations to plan for

  • Shaft, pit and overhead must match the chosen capacity — retrofits may need civil work
  • Busy buildings may need two lifts rather than one larger car
  • Needs regular preventive maintenance to stay safe and reliable

Process

What installation involves

  1. 1Traffic and site survey to size the lift
  2. 2Lift drawing shared with the builder or architect
  3. 3Shaft, pit and power prepared by the building
  4. 4Installation of rails, machine, car, doors and controller
  5. 5Testing, commissioning and handover
More on elevator installation

What affects elevator technology selection and cost?

Factors that affect cost
FactorEffect on cost
Number of stops and travel heightMore floors means longer rails, more landing doors and more wiring
Load and cabin sizeA larger car needs a bigger machine, stronger structure and wider shaft
Drive and machine locationMRL, machine-room traction and other drives differ in equipment and civil cost
Door typeAutomatic doors cost more than manual doors; wider openings add cost
Cabin finishStainless steel, glass, wood and gold finishes are priced differently
Civil and electrical workShaft construction, pit, overhead and the power connection are often separate costs

We don't publish generic prices: a written quotation follows the site survey. See elevator cost factors.

Safety

Safety and verification

  • Automatic Rescue Device (ARD) to bring the car to a floor during power failure
  • Electrical door interlocks on car and landing doors
  • Emergency light, alarm and communication in the car

The control panel, ARD, COP and LOP used by GEVS are declared IS 17900-compatible by our component supplier, Inditech.

How our safety and control systems work

Maintenance

A society or office lift makes hundreds of trips a day, so scheduled maintenance is essential. An AMC covers preventive visits, safety checks and breakdown attendance, with parts handled according to the contract type.

Learn about elevator AMC plans

Documents

Downloads

FAQs

Frequently asked questions

How many passenger lifts does a residential building need?

It depends on the number of floors, flats per floor and how many people use the lift at peak times. A single tower may need one or more lifts. We assess the expected traffic during the site consultation and recommend the number and capacity of lifts in writing.

Can a passenger lift be installed in an existing building?

Often, yes, provided a shaft can be created or an existing one reused, with enough pit depth and overhead height for the chosen lift. A site survey confirms what fits. Where the old shaft is smaller than today's lifts need, the car size is chosen to suit it.

Shaft, pit and overhead requirements →

Should a society choose an MRL or machine-room lift?

Machine room-less (MRL) lifts suit most low- and mid-rise buildings because they need no room on the roof. Taller or faster installations may favour a machine room. We compare both for your building during the consultation and explain the trade-offs.

MRL vs traction elevators compared →

Next step

Discuss elevator technology with GEVS.

Share the building type, number of floors, available shaft dimensions and power details. GEVS can review the project requirements and confirm the next steps.

Written by the GEVS team · Last reviewed: · GEVS – Gauri Enterprises Vertical Solutions, based in Pimpri Chinchwad, Pune

Get a Quote